Page 13 - SKF-insert-bearing-units
P. 13
Insert bearing langed units with 4-bolt lange housing, set screws, for metric shaft Extract from PUB 17277 EN
d 20 – 90 mm
A A 5 N
s 1
d
B
G
J
L
A 1
T
Principal Basic load ratings Fatigue load Limiting speed Mass Designations
dimensions dynamic static limit with shaft Housing Bearing Appropriate Unit
tolerance h6 end cover
d C C 0 P u
mm kN r/min kg –
20 12,7 6,7 0,3 6 500 0,49 F 204 UC 204 ECY 204 UCF 204
25 14,0 7,8 0,3 5 850 0,63 F 205 UC 205 ECY 205 UCF 205
30 19,5 11,4 0,5 5 000 0,89 F 206 UC 206 ECY 206 UCF 206
35 25,5 15,3 0,7 4 300 1,25 F 207 UC 207 ECY 207 UCF 207
40 32,5 20,0 0,9 3 750 1,69 F 208 UC 208 ECY 208 UCF 208
45 32,5 20,4 0,9 3 400 1,96 F 209 UC 209 ECY 209 UCF 209
50 35,1 23,2 1,0 3 300 2,23 F 210 UC 210 ECY 210 UCF 210
55 43,6 29,0 1,3 3 000 3,60 F 211 UC 211 ECY 211 UCF 211
60 52,7 36,0 1,5 2 700 3,97 F 212 UC 212 ECY 212 UCF 212
65 57,2 40,0 1,7 2 350 5,08 F 213 UC 213 ECY 213 UCF 213
70 62,4 44,0 1,9 2 250 5,34 F 214 UC 214 ECY 214 UCF 214
75 66,3 49,0 2,0 2 100 5,86 F 215 UC 215 ECY 215 UCF 215
80 71,5 54,0 2,2 1 900 7,02 F 216 UC 216 ECY 216 UCF 216
85 83,2 64,0 2,5 1 800 8,91 F 217 UC 217 ECY 217 UCF 217
90 95,6 72,0 2,7 1 600 11,38 F 218 UC 218 ECY 218 UCF 218
13