Page 19 - SKF-insert-bearing-units
P. 19
Insert bearing langed units with oval 2-bolt lange housing, set screws, for metric shafts Extract from PUB 17274 EN
d 20 – 90 mm
Principal Basic load ratings Fatigue load Limiting speed Mass Designations
dimensions dynamic static limit with shaft Housing Bearings Appropriate Units
tolerance h6 end cover
d C C 0 P u
mm kN r/min kg –
20 12,7 6,7 0,3 6 500 0,44 FL 204 UC 204 ECY 204 UCFL 204
25 14,0 7,8 0,3 5 850 0,62 FL 205 UC 205 ECY 205 UCFL 205
30 19,5 11,4 0,5 5 000 0,90 FL 206 UC 206 ECY 206 UCFL 206
35 25,5 15,3 0,7 4 300 1,19 FL 207 UC 207 ECY 207 UCFL 207
40 32,5 20,0 0,9 3 750 1,53 FL 208 UC 208 ECY 208 UCFL 208
45 32,5 20,4 0,9 3 400 1,84 FL 209 UC 209 ECY 209 UCFL 209
50 35,1 23,2 1,0 3 300 2,17 FL 210 UC 210 ECY 210 UCFL 210
55 43,6 29,0 1,3 3 000 3,12 FL 211 UC 211 ECY 211 UCFL 211
60 52,7 36,0 1,5 2 700 3,99 FL 212 UC 212 ECY 212 UCFL 212
65 57,2 40,0 1,7 2 350 4,93 FL 213 UC 213 ECY 213 UCFL 213
70 62,4 44,0 1,9 2 250 5,46 FL 214 UC 214 ECY 214 UCFL 214
75 66,3 49,0 2,0 2 100 5,99 FL 215 UC 215 ECY 215 UCFL 215
80 71,5 54,0 2,2 1 900 7,52 FL 216 UC 216 ECY 216 UCFL 216
85 83,2 64,0 2,5 1 800 8,83 FL 217 UC 217 ECY 217 UCFL 217
90 95,6 72,0 2,7 1 600 10,70 FL 218 UC 218 ECY 218 UCFL 218
19