Page 59 - Y-bearing-units
P. 59

Mounting instructions                                             Fig. 1
        for Y-bearing plummer                                                     1
        block units
        with a cast housing and an eccentric locking
        collar
        1  Mount any components that are on the
           shaft between the two Y-bearing units.
        2  With the eccentric locking collar removed,
           slide the Y-bearing plummer block unit onto
           the shaft with the locking device facing
           outwards.
        3  Position the Y-bearing unit on the support
           surface. Fit the attachment bolts or nuts but
           do not tighten them.
        4  Mount the other Y-bearing plummer block
           unit on the other end of the shaft, following                  Fig. 2
           steps 2 and 3.
        5  Carefully align both Y-bearing units, using
           the shaft. Fully tighten the attachment bolts
           or nuts in the housing base.
        6  Align the shaft in the bearing arrangement
           axially and – if possible – turn it a few times.
        7  Place the eccentric locking collars on the
           inner ring extension of both Y-bearing units
           and snug tighten them in the main direction
           of rotation († fig. 1).
        8  Tighten the locking collars to their final
           position, using a hook spanner with a stud
           engaging the hole in the circumference of
           the collar († fig. 2).
        9  Tighten the grub screw in the eccentric
           locking collar of both Y-bearing units
           († fig. 3) to the tightening torque indicated
           in table 1 on page 54.                                         Fig. 3
        10  If applicable, snap the end cover(s) into
           place.


















                                                                            57