w asher. Hexagonal head bolts in accordance                       Fig. 2
        with ISO 4014:1999 are appropriate. Alterna-
        tively, hexagonal socket head cap screws in                               1
        accordance with ISO 4762:1988 can be used
        († fig. 1).

        Assembling units
        In cases where the Y-bearing and composite
        or cast Y-housing are not supplied as a unit, the
        first step is to assemble the bearing into the
        housing. To do this, start by removing the locking
        collar if the bearing has one. Then insert the
        bearing into the filling slot in the housing bore
        († fig. 2) and with a round piece of wood or
        pipe, swivel the bearing into position so that the
        locking device is facing in the same direction as
        the filling slots († fig. 3). When installing
        standard bearings, make sure that the relubri-                    Fig. 3
        cation hole in the bearing on the side of the
        locking device does not coincide with the filling
        slot in the housing, otherwise grease leakage
        may result († fig. 4).















                                                                          Fig. 4