Page 64 - Y-bearing-units
P. 64

Mounting instructions

        Mounting instructions
        for Y-bearing plummer
        block units
        with a pressed steel housing and
        an eccentric locking collar
        1  Mount any components that are on the
           shaft between the two Y-bearing units.
        2  With the eccentric locking collar removed,
           slide the Y-bearings onto both shaft ends
           with the locking device facing outwards.
           Install the rubber seating ring on the out-
           side diameter of the bearing (optional).
        3  Place the base of each housing on its sup-
           port surface.
        4  Place the shaft and Y-bearings into position
           in each housing base. Then, place the housing
           caps over the bearings († fig. 1) and
           install the attachment bolts or nuts.
        5  Carefully align both Y-bearing units, using
           the shaft. Then, tighten the attachment
           bolts or nuts.
        6  Align the shaft in the bearing arrangement
           axially and – if possible – turn it a few times.
        7  Place the eccentric locking collars on the
           inner ring extension of both Y-bearings and
           snug tighten them in the main direction of
           rotation († fig. 2).
        8  Tighten the locking collars to their final
           position, using a hook spanner with a stud
           engaging the hole in the circumference of
           the collar († fig. 3).
        9  Tighten the grub screw in the eccentric
           locking collar of both Y-bearings († fig. 4)
           to the tightening torque indicated in table 1
           on page 54.



















        62