Page 67 - Y-bearing-units
P. 67

Mounting instructions                                             Fig. 1
        for flanged Y-bearing units
                                                                                  1
        with a composite (Y-TECH) or cast housing
        and an eccentric locking collar

        1   Mount any components that are on the
           shaft between the two Y-bearing units.
        2   With the eccentric locking collar removed,
           slide the flanged Y-bearing unit onto the
           shaft with the locking device facing
           outwards.
        3   Fasten the Y-bearing unit securely to the
           machine wall.
        4   Mount the other flanged Y-bearing unit
           to the opposite end of the shaft, following
           steps 2 and 3.
        5   Align the shaft in the bearing arrangement                    Fig. 2
           axially and – if possible – turn it a few times.
        6  Place the eccentric locking collars on the
           inner ring of both Y-bearings and snug
           tighten them in the main direction of rotation
           († fig. 1).
        7  Tighten the locking collars to their final
           position using a hook spanner with a stud
           engaging the hole in the circumference of
           the collar († fig. 2).
        8  Tighten the grub screw in the eccentric
           locking collar of both units († fig. 3) to the
           tightening torque indicated in table 1 on
           page 54.
        9  If applicable, snap the end cover(s) into
           place.


                                                                          Fig. 3




















                                                                            65
   62   63   64   65   66   67   68   69   70   71   72