Page 49 - Single-line automatic lubrication systems
P. 49

Overview of grease pumps and pump units


                                                                                                                      Pump units for grease


            Manually operated pump units
            Product    Lubricant  Metering quantity    Operating pressure   Reservoir  Metering device   Piston  Page
                       NLGI    max.              max.                         category  1)
                       0 1 2   cm 3 /stroke in 3 /stroke  bar  psi  kg  lib   4 5 6 7

            83817      • • •   1,6      0.09     240   3500     0,5  1        – • • •       multiple stroke  52
            1810       • • •   2,6      0.16     240   3500     2,3  5        – • • •       multiple stroke  53
            1)   Select the recommended fittings, adjust the pump pressure within the recommended metering device pressure range


            Air–operated pump units
            Product      Lubricant  Metering quantity    Operating pressure  Reservoir  Metering device  Piston  Page
                         NLGI    max.            max.                               category  1)
                          0 1 2  cm 3 /stroke in 3 /stroke  bar  psi  kg  lib       4 5 6 7

            40PGA        • • •   40      2.44    10   145      1,7; 2; 4; 10  3.7; 4.4; 8.8; 22  – • • •  single stroke  54
            82886, 83886  • • •  7,4     0.45    240  3 500    0,5; 2,0  1; 4.4     – • • •     single stroke  56
            85442      2) • • •  7,4     0.45    240  3 500    0,5      1           – • • •     single stroke  57
            85444/45     • • •   7,4     0.45    240  3 500    1,8      4           – • • •     single stroke  58
            85434/35/36  • • •   18,7; 35,2 1.14; 2.15  240  3 500  2,0  4.5        – • • •     single stroke  59
            82653/55     • • •   22,9    1.39    240  3 500    2,0      4.5         – • • •     single stroke  60
            83800/34     • • •   35,2    2.15    240  3 500    2,0      4.5         – • • •     single stroke  60
            83167        • • •   197     12      240  3 500    5,0      11          – • • •     reciprocating  61
            83599        • • •   197     12      240  3 500    5,0      11          – • • •     reciprocating  62
            1)   Select the recommended fittings, adjust the pump pressure within the recommended metering device pressure range
            2)   Controller included or optional


            Hydraulically operated pump units
            Product      Lubricant  Metering quantity    Operating pressure  Reservoir  Metering device  Piston  Page
                         NLGI    max.            max.                               category  1)
                          0 1 2  cm 3 /stroke in 3 /stroke  bar  psi  kg  lib       4 5 6 7

            HG 1000      • • –   1 000   61.02   150  2 176    1,0      2.2         • • – –     single stroke  63
            HG 2000      • • –   2 000   122     150  2 176    2,0      4.4         • • – –     single stroke  63
            84944, 84961  • • •  180     11      206  3 000    30       60          – • • •     reciprocating  64
            84960, 84962  • • •  180     11      206  3 000    –        –           – • • •     reciprocating  65
            FlowMaster   • • •   737     45      206  3 000    16; 27; 41;    35; 60; 90;    – • • •  reciprocating  66
                                                               54; 180   120; 400


            Air–operated barrel pumps

            Product     Lubricant  Metering quantity    Operating pressure  Reservoir  Metering device  Piston  Page
                        NLGI    max.           max.                                category  1)
                        0 1 2   cm 3 /min  in 3 /min  bar  psi  kg     lb          4 5 6 7

            MPB         • • •   305     18.61  300   4 350   18; 50; 180  40; 120; 400  – • • •  reciprocating  68
            84050/ 85460  • • •  492    30     240   3 500   27        60          – • • •    reciprocating  70
            282288      • • •   492     30     240   3 500   55        120         – • • •    reciprocating  71
            FlowMaster  • • •   737     45     206   3 000   16; 27; 41;    35; 60; 90;    – • • •  reciprocating  72
                                                             54; 180   120; 400
            1)   Select the recommended fittings, adjust the pump pressure within the recommended metering device pressure range
            2)   Controller included or optional

                                                             49
   44   45   46   47   48   49   50   51   52   53   54