Page 46 - Single-line automatic lubrication systems
P. 46
Pump unit
MFE
Pump units for oil
Description
Technical data
The gear pump units comprising the MFE series are designed
to supply lubricant used in intermittently operated, single-line cen- Function principle electrically operated gear pump
1
Outlets
tralized lubrication systems. The basic setup includes a gear pump Metering quantity 250 to 500 cm 3 / min, 15 to 31 in 3 / min
unit with motor, a 3- or 6 l lubricant reservoir in metal or plastic, or a Lubricant oil 5 to 2 000 mm 2 / s and fluid grease
NLGI 00, 000
15 l metal reservoir and float switch to monitor the minimum per-
Operating temperature –10 to +60 °C; +14 to +140 °F
missible level of lubricant. In addition to the basic models, units can Back pressure max. 17,5; 28 bar
be outfitted with add-ons. max. 255, 405 psi
Reservoir 3; 6; 15 l, 0.8, 1.6, 4 gal
Material (reservoir) plastic, metal
Connection outlet M 14×1.5
Features and benefits Operating voltage 230/400 V AC
Protection class IP 54
• Integrated float switch for fill-level monitoring Dimensions:
3 l; 0.8 gal plastic reservoir 303 × 130 × 245 mm; 11.9 × 5.1 × 9.6 in
• Integrated pressure-relief valve and pressure-regulating valve 3 l; 0.8 gal metal reservoir 332 × 178 × 312 mm; 13 × 7 × 12.3 in
• Motors available for various voltage ranges and approvals 6 l; 1,5 gal plastic reservoir 319 × 128 × 265 mm; 12.6 × 5 × 10.4 in
6 l; 1,5 gal metal reservoir 370 × 167 × 330 mm; 14.6 × 6.6 × 12.9 in
• Special designs offered for a wide range of applications 15 l; 4 gal metal reservoir 453 × 200 × 436 mm; 17.8 × 7.8 × 17.2 in
Mounting position vertical
• Suitable for intermittent operation
Floating switch for low-level monitoring of oil
• For remote installation out of reservoir or for built-in reservoir Type of contact 1 change-over;
2 change-over contacts (reed contacts)
• Reliable and versatile Switching voltage max. 230 V AC, 230 V DC
Switching current max. 0,8 A; 1,0 A
• Suitable for use with metering devices of category 1 and 2 Switching capacity max. 60 VA, 40 W 1)
Type of enclosure IP 65
Applications 1) Take appropriate measures to protect contacts when switching inductive loads
• Automotive manufacturing
NOTE
• Metal, including presses
Further technical information, technical drawings,
• Machine tools accessories, spare parts or product function descriptions
• Printing and finishing available on SKF.com/lubrication:
1-1202-EN, 951-170-002 EN