Page 51 - Single-line automatic lubrication systems
P. 51

Overview of grease pumps and pump units


                                                                                                                      Pump units for grease Pump units for grease


            Electrically operated pump units
            Product     Lubricant  Metering quantity    Operating pressure  Reservoir  Metering device  Voltage  Page
                        NLGI    max.            max.                               category  1)
                        0 1 2   cm 3 /min  in 3 /min  bar  psi  kg      lb         4 5 6 7

            P603S    2) 3) • • •  12    0.7     300   4 350   4; 8; 10;    8.8; 18; 22;    – • • •  12 / 24 V DC  74
                                                              15; 20   33; 44
            Minilube  2)  • • –  13     0.8     250   3 625   2         4.4        – • • •     12 / 24 V DC  76
            KFG         • • •   15      0.9     300   4 350   2; 4; 6; 8; 10;  4.4; 8.8; 13; 18;  – • • •  12 / 24 V DC;   78
                                                              12; 15; 20  22; 26; 33; 44       90-264 V AC
            Multilube  2)  • • –  16    0.976   200   2 900   4; 10     8.8; 22    – • • •     24 V DC;   80
                                                                                               115 / 230 V AC
            P653S    2) 3) • • •  24,6  1.5     317   4 600   4; 8; 15; 20  8.8; 18; 22; 44  – • • •  24 V DC;   82
                                                                                               120 / 230 V AC








            1)   Select the recommended fittings, adjust the pump pressure within the recommended metering device pressure range
            2)   Controller included or optional
            3)   Stainless steel or C5M available

            Electrically operated barrel pumps

            Product     Lubricant  Metering quantity    Operating pressure  Reservoir  Metering device  Voltage  Page
                        NLGI    max.            max.                               category  1)
                        0 1 2   cm 3 /min  in 3 /min  bar  psi  kg      lb         4 5 6 7


            E-PUMP      • • •   55      3.35    240   3 480   18, 50, 180  40; 120; 400  – • • •  20–32 V DC  84
            FK       2)  • • •  74      4.5     400   5 800   15; 30; 60  22; 66; 132  – • • •  3 phase drive  86
            FlowMaster  • • •   103     6.3     345   5 000   16; 25; 28;   35; 55; 60; 78;   – • • •  12 / 24 V DC;   88
                                                              35; 40; 55;   90; 120; 400       120-460 V AC
                                                              180






            1)   Select the recommended fittings, adjust the pump pressure within the recommended metering device pressure range
            2)   Controller included or optional
            3)   Stainless steel or C5M available















                                                             51
   46   47   48   49   50   51   52   53   54   55   56