Page 52 - Single-line automatic lubrication systems
P. 52

Pump unit


        83817
     Pump units for grease






























        Description
                                                              Technical data
        This manual pump unit has a metal reservoir and a spring-loaded
        follower. The indicator pin in the pump base shows when 172 bar    Order number  83817
        (2 500 psi) system operating pressure has been achieved.  Function principle  manually operated piston pump
                                                              Outlets             1
                                                              Metering quantity   1,6 cm  3 / stroke, 0.10 in  3 / stroke
        Features and benefits                                 Lubricant           grease NLGI 0, 1, 2
                                                              Operating temperature  –20 to +65 °C, –4 to +149 °F
        •  Number of strokes dependent on connected           Operating pressure  min. 82 bar, 1 200 psi
                                                                                  max. 240 bar, 3 500 psi
          lubrication points and their dosage                 Reservoir           0,5 kg, 1 lb
                                                              Material            steel, brass, copper, polyurethane, nitrile
        •  Metal reservoir with spring-loaded follower also suitable    Filling method  0,4 kg, 14.5 oz, grease cartridge/bulk fill
          for replaceable 400 g grease cartridges             Connection outlet   1 /8 NPTF (F)
                                                              Dimensions          387 × 127 × 141 mm
        •  Simple handling                                                        15.25 × 5 × 5.625 in
                                                              Mounting position   vertical or horizontal
        •  Low-cost, efficient method of lubricant distribution
        •  Pump base with built-in check vent valve and indicator pin
          for visual control of max. or vent pressure
        •   Vents when handle is pushed all the way back
        •  Two different filling couplers available
        •  For use with metering devices of category 5, 6, 7


        Applications
        •  Construction machinery
        •  Agriculture
                                                                   NOTE
                                                                     Further technical information, technical drawings,
                                                                   accessories, spare parts or product function descriptions
                                                                   available on SKF.com/lubrication.