Page 52 - Single-line automatic lubrication systems
P. 52
Pump unit
83817
Pump units for grease
Description
Technical data
This manual pump unit has a metal reservoir and a spring-loaded
follower. The indicator pin in the pump base shows when 172 bar Order number 83817
(2 500 psi) system operating pressure has been achieved. Function principle manually operated piston pump
Outlets 1
Metering quantity 1,6 cm 3 / stroke, 0.10 in 3 / stroke
Features and benefits Lubricant grease NLGI 0, 1, 2
Operating temperature –20 to +65 °C, –4 to +149 °F
• Number of strokes dependent on connected Operating pressure min. 82 bar, 1 200 psi
max. 240 bar, 3 500 psi
lubrication points and their dosage Reservoir 0,5 kg, 1 lb
Material steel, brass, copper, polyurethane, nitrile
• Metal reservoir with spring-loaded follower also suitable Filling method 0,4 kg, 14.5 oz, grease cartridge/bulk fill
for replaceable 400 g grease cartridges Connection outlet 1 /8 NPTF (F)
Dimensions 387 × 127 × 141 mm
• Simple handling 15.25 × 5 × 5.625 in
Mounting position vertical or horizontal
• Low-cost, efficient method of lubricant distribution
• Pump base with built-in check vent valve and indicator pin
for visual control of max. or vent pressure
• Vents when handle is pushed all the way back
• Two different filling couplers available
• For use with metering devices of category 5, 6, 7
Applications
• Construction machinery
• Agriculture
NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF.com/lubrication.
52