Page 44 - Single-line automatic lubrication systems
P. 44

Pump unit


        MKF
     Pump units for oil





























        Description
                                                              Technical data
        MKF gear pump units are used in single-line systems to supply
        fluid greases NLGI 000 and 00 and include a pressure-regulating   Function principle  electrically operated gear pump
                                                              Metering quantity
                                                                                  100; 200; 500 cm  3 / min
        valve and pressure-relief valve. Electrical pressure monitoring is        6; 12; 31 in  3 / min
        performed by an integrated pressure switch, and fill-level monitoring   Lubricant  fluid grease NLGI 000 or 00, compatible
                                                                                  with plastics, NBR elastomers, copper
        also is possible. These units are controlled externally via the machine
                                                                                  and copper alloys
        control system or an integrated control unit. Also, MKF units can be   Operating temperature  +10 to +40 °C; +50 to +104 °F
        supplied with a pushbutton to activate interim lubrication at any   Operating pressure  max. 30 bar, 435 psi
        time. Main functions are integrated into the lid, and a plastic cap    Reservoir  2,0; 3,0 and 6,0 l, 0.5, 0.8 and 1.6 gal
                                                                                  plastic, metal
                                                              Material (reservoir)
        protects the electrical components from contaminants such as    Connection outlet  G  1 /4
        dirt and dust.                                        Operating voltage   24 V DC; 115 V AC; 230 V AC
                                                              Protection class    IP 54
                                                              Dimensions:
        Features and benefits                                 pump unit with
                                                              2 l; 0.5 gal plastic reservoir  204 × 130 × 298 mm
        •  Integrated pressure-limitation and pressure-relief valve               8 × 5.2 × 11.7 in
                                                              3 l; 0.8 gal plastic reservoir   286 × 132 × 298 mm
        •  Optional: electrical pressure switch, pressure gauge, float switch     11.3 × 5.2 × 11.7 in
                                                              3 l; 0.8 gal metal reservoir  286 × 132 × 313 mm
        •  External control via SPS or by means of internal                       11.3 × 5.2 × 12.3 in
          control unit possible                               6 l; 1,5 gal plastic reservoir  290 × 178 × 334 mm
                                                                                  11.4 × 7 × 13.2 in
        •  All important functions integrated into the lid    Mounting position   vertical
        •  Modular construction

        Applications

        •  Material handling
                                                                   NOTE
        •  Automotives
                                                                     Further technical information, technical drawings,
        •  Machine tool                                            accessories, spare parts or product function descriptions
        •  Printing and finishing                                  available on SKF.com/lubrication:
                                                                   1-1203-EN, 951-170-005 EN
        •  Industrial assembly and automation
                                                                  3D
        •  Textiles
                                                                  skf-lubrication partcommunity com/3d-cad-models