Page 84 - Single-line automatic lubrication systems
P. 84

Pump unit


        E-PUMP
     Pump units for grease






























        Description
                                                              Technical data
        The electrical barrel pumping unit E-PUMP is a versatile barrel
        pump and it is especially designed for pumping oil or grease lubri-  Function principle  electrically operated pump
        cants up to NLGI grade 2 into a centralized lubrication system. When   Outlets  1 4
                                                              Number of pump elements
        equipped with a change-over valve unit, as E-VALV e.g. or a shut-off   Metering quantity  55 g/min; 0.3880136 oz/min
        valve as E-VALVE-S e.g. it can be used either in single-line, dual-line   Operating temperature  –30 to +70 °C, -20 to 160 °F
                                                              Operating pressure  max. 240 bar, 3 480 psi
        or progressive lubrication systems. A complete pumping center con-  Lubricant  grease up to NLGI 2
        sists of a pumping unit and a lid set. EPUMP-XXX-ECO coding is            oil up 40–1 000 mm 2 /s
        referring to ECO lid sets (descending pump head with follower plate),   Operating voltage  20–32 V DC
                                                              Power consumption
                                                                                  150 W
        which are suitable for greases in NLGI grades 1 and 2 while EPUMP-  Heater  40W / 24V, heater resistor
        XXX-STA coding is referring to STA lid sets (pump head always at          for pump elements in ECO models
                                                              Display             LED’s 5 yellow, 1 green, 1 red
        barrel bottom), which are suitable for oil or greases in NLGI 0, 00
                                                              Drum capacity       18, 50 and 180 kg, 40, 120 or 400 lb
        and 000 classes.                                                          drum not included
                                                              Pressure sensor     50-240 bar adjustable in 25 bar steps
                                                                                  725.1 to 3480.9 psi in 362.6 psi steps
        Features and benefits                                 Protection class    IP 65
                                                              Dimensions          depending on the model
                                                                                  min. 400 × 400 × 800 mm
        •  EPUMP models reflecting typical and often used barrel sizes
                                                                                  max. 400 × 400 × 1 300 mm
        •  Compact electrically operated pump for applications where no           min. 15.75 × 15.75 × 31.49 in
          air supply is available                             Mounting position   max. 15.75 × 15.75 × 51.18 in
                                                                                  vertical
        •  An internal pressure control and a heating element secure the
          pump’s function in high-pressure conditions and cold climates

        Applications
        •  Heavy industries (paper, steel and other process industries)
                                                                   NOTE
        •  Mining and mineral processing                             Further technical information, technical drawings,
        •  Machinery workshops                                     accessories, spare parts or product function descriptions
                                                                   available on SKF.com/lubrication
        •  Food and beverage
        •  Cement industry





                                                           84
   79   80   81   82   83   84   85   86   87   88   89