Page 79 - Single-line automatic lubrication systems
P. 79
Pump unit
KFG
Pump units for grease
Position of pump elements
K F G +
Identification code
1 2 3
Product series
Integrated control unit
X = No control unit L = LC502
Reservoir
1 = 2 kg, 4 lb (not available for
rotary application version)
2 = 4 kg, 9 lb (only rotary application version)
3 = 6 kg, 13 lb
4 = 8 kg, 18 lb (only rotary application version)
5 = 10 kg, 22 lb
6 = 12 kg, 26 lb (only rotary application version)
7 = 15 kg, 33 lb
8 = 20 kg, 44 lb (not available for
rotary application version)
Range of application
R = Rotary M = Industry F = Vehicle
application application application
Filling
X = Without lubricant (not available for rotary application version)
A = Grease NLGI-Grade 2 for vehicles (not for capacitive fill-level monitor)
F = Customized grease
Fill-level monitor
X = Without fill-level monitor
1 = Mechanical level monitor (not available for rotary application version)
2 = Mechanical level monitor with signal smoothing (not available for rotary version;
only possible with KFGX)
3 = Capacitive level monitor (only available for industry versio with 2 and 6 kg reservoir)
4 = Cylinder switch level monitor (only available for rotary application version)
Pump element or filler socket
Spring-return piston pump Positively driven piston pump
X = No pump element Y = No pump element
E = 5,0 cm 3 / min; 0,30 in 3 / min L = 5,0 cm 3 / min; 0,30 in 3 / min
W = Socket for filling cylinder V = Socket for filling cylinder
(not available for rotary application version) (not available for rotary application version)
Fitting for main line connection and valves 3)
S = Pressure relief and restriction valve (200 bar/2 900 psi) with SKF Quick Connector for ∅ 6 mm tubes
T = Pressure relief and restriction valve (200 bar/2 900 psi) with SKF Quick Connector for ∅ 8 mm tubes
U = Pressure relief and restriction valve (200 bar/2 900 psi) with solderless pipe union for ∅ 10 mm tubes
V = Pressure relief and restriction valve (200 bar/2 900 psi) with solderless pipe union for ∅ 8 mm tubes
W = Pressure relief and restriction valve (200 bar/2 900 psi) with female thread solderless pipe union
for ∅ G 1/4 tubes 2)
Pump cycle / interval time
No control unit LC502
99 = none EB = 4 min. run time / 1 h interval time. Factory setting, additional setting times on request
Voltage key
912 = 12 V DC (only available for vehicle application version) 924 = 24 V DC 486 = 90–264 V AC (not available for vehicle application version)
1) For technical reasons, the first pump element must always be installed at outlet 1 in SKF MonoFlex systems
2) If the relief valve is configured together with several pump elements, then the lines leading from the pump elements will be joined together ahead of the relief valve
79