Page 79 - Single-line automatic lubrication systems
P. 79

Pump unit


           KFG
                                                                                                                      Pump units for grease



            Position of pump elements




                             K F G                                                            +
            Identification code


                                                                 1    2    3
            Product series
            Integrated control unit
              X = No control unit   L = LC502
            Reservoir
              1 = 2 kg, 4 lb (not available for
                rotary application version)
              2 = 4 kg, 9 lb (only rotary application version)
              3 = 6 kg, 13 lb
              4 = 8 kg, 18 lb (only rotary application version)
              5 = 10 kg, 22 lb
              6 = 12 kg, 26 lb (only rotary application version)
              7 = 15 kg, 33 lb
              8 = 20 kg, 44 lb (not available for
                rotary application version)
            Range of application
              R = Rotary    M = Industry    F = Vehicle
              application    application   application
            Filling
              X = Without lubricant (not available for rotary application version)
              A = Grease NLGI-Grade 2 for vehicles (not for capacitive fill-level monitor)
              F = Customized grease
            Fill-level monitor
              X = Without fill-level monitor
              1 = Mechanical level monitor (not available for rotary application version)
              2 = Mechanical level monitor with signal smoothing (not available for rotary version;
                 only possible with KFGX)
              3 = Capacitive level monitor (only available for industry versio with 2 and 6 kg reservoir)
              4 = Cylinder switch level monitor (only available for rotary application version)
            Pump element or filler socket
              Spring-return piston pump         Positively driven piston pump
              X = No pump element               Y = No pump element
              E = 5,0 cm  3 / min; 0,30 in  3 / min  L = 5,0 cm  3 / min; 0,30 in  3 / min
              W = Socket for filling cylinder   V = Socket for filling cylinder
                 (not  available for rotary application version)  (not  available for rotary application version)
            Fitting for main line connection and valves  3)
              S = Pressure relief and restriction valve (200 bar/2 900 psi) with SKF Quick Connector for ∅ 6 mm tubes
              T = Pressure relief and restriction valve (200 bar/2 900 psi) with SKF Quick Connector for ∅ 8 mm tubes
              U = Pressure relief and restriction valve (200 bar/2 900 psi) with solderless pipe union for ∅ 10 mm tubes
              V = Pressure relief and restriction valve (200 bar/2 900 psi) with solderless pipe union for ∅ 8 mm tubes
              W = Pressure relief and restriction valve (200 bar/2 900 psi) with female thread solderless pipe union
                 for ∅ G 1/4 tubes  2)
            Pump cycle / interval time
              No control unit      LC502
              99 = none            EB = 4 min. run time / 1 h interval time. Factory setting, additional setting times on request
            Voltage key
              912 = 12 V DC (only available for vehicle application version)  924 = 24 V DC  486 = 90–264 V AC (not available for vehicle application version)

            1)   For technical reasons, the first pump element must always be installed at outlet 1 in SKF MonoFlex systems
            2)   If the relief valve is configured together with several pump elements, then the lines leading from the pump elements will be joined together ahead of the relief valve

                                                             79
   74   75   76   77   78   79   80   81   82   83   84