Page 75 - Y-bearing-units
P. 75

Mounting instructions
        for Y-bearing take-up units
                                                                                  1
        with a cast housing and an eccentric locking
        collar

        1  Mount any components that are on the
           shaft between the two Y-bearing units.
        2  With the eccentric locking collar removed,
           slide the Y-bearing take-up units onto both
           shaft ends with the locking device facing
           outwards.
        3  Install the shaft with the Y-bearing take-up
           units into the take-up frames and connect
           the adjustment screws via the cast hole in
           the units.
        4  Align the shaft in the bearing arrangement
           axially and – if possible – turn it a few times.
        5  Place the eccentric locking collars on the
           inner ring extension of both Y-bearing units
           and snug tighten them in the main direction
           of rotation.
        6  Tighten the locking collars to their final
           position using a hook spanner with a stud
           engaging the hole in the circumference of
           the collar.
        7  Tighten the grub screw in the eccentric
           locking collar of both Y-bearing units to the
           tightening torque indicated in table 1 on
           page 54.
        8  If applicable, snap the end cover(s) into
           place.

























                                                                            73
   70   71   72   73   74   75   76   77   78   79   80