Page 8 - Single-line automatic lubrication systems
P. 8

Single-line lubrication systems for oil and fluid grease




                                                                                                     System video



     Introduction




































        System description

        Regardless of the application, the principle of single-line lubrication   SKF application engineers, as well as SKF sales partners
        remains the same: a central pump station automatically delivers   and distributors, are experts in laying out lubrication systems
        lubricant through a single supply line to the lubricant metering   according to all these specifications. A lubrication system laid out by
        device. Each metering device serves only one lubrication point and   SKF and partners ensures the supply of the correct amount of lubri-
        may be adjusted to deliver the precise amount of grease or oil   cant at the best time to lubricate. This reduces wear and avoids pol-
        required. Systems can service one machine, different zones on one   lution caused by over-lubrication.
        machine or even several separate machines. The SKF portfolio
        includes both SKF MonoFlex and Lincoln Centro-Matic system com-  Advantages:
        ponents including pumps, metering units, control and monitoring
        devices and accessories.                             •  Easy to understand, install and maintain
        For planning a lubrication system, conditions the system will be used   •  Available in both preset and adjustable models
        in need to be determined first.  The number of lubrication points,
                                                             •  Suitable for almost all lubricants
        back  pressures at the lubrication points, operating temperature
                                                             •  Easy system expansion
        range, lubricant, the feed pump’s drive energy, control and monitor-
        ing etc. need to be defined correctly. Attention to information on   •  System continues to operate if one point becomes blocked
        bearing or lubrication point information need to be paid too. The sum   •  Integrated system control and monitoring
        of all the quantities metered out by the system’s metering devices
        needs to be completed by safety margin and  expansion and com-  •  Able to pump long distances and within a wide
        pressibility loss.                                     temperature range








                                                            8
   3   4   5   6   7   8   9   10   11   12   13