Page 13 - Single-line automatic lubrication systems
P. 13

Overview of oil and fluid grease pumps and pump units





                                                                                                                      Pump units for oil
            Manually operated pump units
            Product  Lubricant     Metering quantity    Operating pressure   Reservoir     Metering device   Page
                                   max.                max.                                category  1)
                     oil   fluid grease  cm 3 /stroke  in 3 /stroke  bar  psi  l  gal       1  2  3  4

            MCP     •   –          15        0.91      38   551      0,5; 1; 1,7  0.13; 0.26; 0.45  ●  ●  ●  –  14
            1812    •   •          2,6       0.16      69   1 000    2,1      0.55         –  ●  ●  ●   16

            1)   Select the recommended fittings, adjust the pump pressure within the recommended metering device pressure range

            Air-operated pumps and pump units
            Product         Lubricant    Metering quantity    Operating    Reservoir        Metering device   Page
                                         max.             pressure max.                     category  1)
                            oil  fluid grease  cm 3 /stroke in 3 /stroke  bar  psi  l  gal  1  2  3  4

            P-846-2         •   –        7       0.42     45  652     –        –            ●  ●  ●  –   17
            283167          •   •        1,97    0.12     69  1 000   7,1      1.88         –  –  ●  ●   18
            82885, 83667    •   •        7,4     0.45     69  1 000   0,6; 2   0.16; 0.53   –  ●  ●  ●   19
            85438 / 40 / 41  2) •  •     7,4     0.45     69  1 000   0,6; 2   0.16; 0.53   –  ●  ●  ●   20
            P/PW/PF/PFW-289  •  •        10      0.61     40  580     1,5      0.39         ●  ●  ●  –   21
            ACP             •   –        15      0.91     38  551     0,5; 1; 1,7  0.13; 0.26; 0.45  ●  ●  ●  –  22
            PPS30           •   •        30      1.83     27  392     1,5      0.39         ●  ●  –  –   24
            P-886           •   –        30      1.83     35  508     –        –            ●  ●  ●  –   26
            82676           •   •        39,3    2.39     69  1 000   –        –            –  –  –  ●   27
            82570           •   •        39,3    2.39     69  1 000   2        0.53         –  –  –  ●   28
            85430 / 31 / 32 / 33 2) •  •  39,3   2.39     69  1 000   0,0; 2   0.0; 0.53    –  –  –  ●   29
            PEF/PEU         •   •        48      2.93     50  725     3        0.79         ●  ●  ●  –   30
            1)   Select the recommended fittings, adjust the pump pressure within the recommended metering device pressure range
            2)   Controller optionally


            Air-operated barrel pumps
            Product         Lubricant    Metering quantity    Operating    Reservoir        Metering device   Page
                                         max.             pressure max.                     category  1)

                            oil  fluid grease  cm 3 /min  in 3 /min  bar  psi  l  gal       1  2  3  4

            1826          2) •  •        7 571   462      69  1 000   200      52.83        –  ●  ●  ●   31
            1)   Select the recommended fittings, adjust the pump pressure within the recommended metering device pressure range
            2)   Controller optionally

            Electrically operated pumps and pump units
            Product       Lubricant   Metering quantity    Operating    Reservoir           Metering device   Page
                                      max.                pressure max.                     category  1)

                          oil  fluid grease  cm 3 /min  in 3 /min  bar  psi  l  gal         1  2  3  4

            ECP           •  •        12         0.73     38  550     0,38     0.086        ●  ●  ●  –   32
            P653S (oil)   2) 3)  •  •  24,6      1.5      240  3500   4; 8     1.05; 2.11   –  ●  ●  ●   34
            KFB       2)  •  •        50         3        38  550     1        0.26         ●  ●  ●  –   36
            KFB-M     2)  •  •        50         3        38  550     1        0.26         ●  ●  ●  –   38
            KFU           •  •        140        8.5      38  550     2,7; 6   0.71; 1.56   ●  ●  ●  –   40
            MKU       2)  •  –        100; 200; 500  6; 12; 31  30  435  2; 3; 6  0.53; 0.79; 1.56  ●  –  –  –  42
            MKF       2)  •  •        100; 200; 500  6; 12; 31  30  435  2; 3; 6  0.53; 0.79; 1.56  ●  ●  –  –  44
            MFE           •  •        250; 500   15; 31   28  405     3; 6; 15  0.79; 1.56; 3.96  ●  ●  –  –  46
            1)   Select the recommended fittings, adjust the pump pressure within the recommended metering device pressure range
            2)   Controller optionally
            3)   With pressure transducer