Page 136 - Single-line automatic lubrication systems
P. 136
Metering devices for grease Metering device
SL-32HV
Description
Technical data
The series SL-32HV (high venting) metering devices are for sin-
gle-line, high-pressure centralized lubrication systems dispensing Function principle metering device
Outlets 1 to 10
petroleum-based lubricants with a viscosity up to NLGI 2 (refer to Metering quantity 0,016 to 0,131 cm 3
Design Guide). Output is externally adjustable. The indicator stem 0.001 to 0.008 in 3
Lubricant grease NLGI 0, 1, 2
permits visual check of metering device operation. Individual meter- Operating temperature max. +93 °C; +200 °F
ing devices can be removed easily for inspection or replacement. Operating pressure 83 to 240 bar, 1 200 to 3 500 psi
Relief pressure 28 bar, 400 psi
Material carbon steel, nitrile packings
Features and benefits Connection main line 1 /4 NPTF (F), 1 /4 NPTF (M)
Connection outlet 1 /8 in O.D. tube
• Shipped with manifolds from 1 to 10 ports Lubricant point solderless pipe connection (DIN 3862)
to match number of lube points Dimensions min. 44,5 × 93 × 52 mm
max. 215 × 93 × 52 mm
• Output is externally adjustable min. 1.8 × 3.6 × 2.1 in
• Indicator stem permits visual check of operation max. 8.5 × 3.6 × 2.1 in
• Can be removed easily for inspection or replacement Mounting position any
• Available in stainless steel SAE 304
Applications
• Food and beverage, industrial automation
• Machine tools, oil and gas
• Steel industry, pulp and paper Order information
• Marine and forestry, construction Order number Designation Outlet
• Wind energy, mobile on-road
83336HV-1 metering device 1
NOTE 83336HV-2 metering device 2
83336HV-3 metering device 3
Further technical information, technical drawings, 83336HV-4 metering device 4
accessories, spare parts or product function descriptions 83336HV-5 metering device 5
83336HV-6 metering device 6
available on SKF.com/lubrication. 83336HV-7 metering device 7
83336HV-8 metering device 8
83336HV-9 metering device 9
83336HV-10 metering device 10
83338HV metering device, single, no manifold 1
83337HV metering device, single replacement –
136