Checking the static load carrying
capacity
For dynamically loaded bearings that have been 1
selected based on requisite life, it is advisable,
where the equivalent static bearing load P 0 is
known, to check that the static load carrying
capacity is adequate using
s 0 = C 0 /P 0
If the s 0 value obtained is less than the recom-
mended guideline value († table 4), then a
larger Y-bearing or Y-bearing unit should be
selected.
37