Page 70 - Dual-line-automatic
P. 70
Dual pressure controller
DPC 1
Pressure sensors
Description
Technical data
The DPC 1 dual pressure controller was designed for dual-line
lubrication systems that use a change-over valve controlled by an Function principle end-of-line-pressure switch unit
end-of-line pressure switch unit The controller increases the energy Operating temperature –25 to 70 °C
–13 to +158 °F
efficiency of the system by matching the operating pressure to the Lubricant oil and grease
ambient conditions As a result, the pump motor only runs for as long Operating or absolute pressuremax 400 bar, 5 800 psi
Differential pressure max 400 bar, 5 800 psi
as is required for pressure buildup In the case of air-operated driven Monitoring time 1 sec to 99 min 59 sec
pumps, compressed air is conserved The DPC 1 controller consists of Cycle 1 min to 99 hh 59 min
a housing with integrated control electronics, an LCD and a mem- Shock resistance 20 g
brane keypad For the operation, there are two pressure Supply voltage 24 V DC, ± 10%
sensors available, which will be installed in each main line Overload protection up to 40 V
EMC DIN EN 61000-6-2 and 61000-6-3
Reverse polarity protection integrated
Protection class IP 65
Features and benefits Dimensions without cable 100 × 100 × 62 mm
glands 3.9 × 3.9 × 2.4 in
• Monitors proper function of system with regard to Mounting position any
pump and change-over valve and detects tube line leaks
• Self-adjusting operating pressure increases service cycle
of system components
• Integrated timer enables system operation
without separate controller
• Measures the absolute min and max in the main lines
• Measures the differential pressure minimum and maximum
• IP 65 protection rating and Shockproof for rigorous environments
NOTE
Applications Further technical information, technical drawings,
accessories, spare parts or product function descriptions
• Paper mills
are available on SKF com/lubrication:
• Steel mills PUB 13597 EN
• Heavy industry
• Beverage industry
70