Electric pressure switch
DW
Pressure sensors
Description
Technical data
Electric pressure switches are used to monitor the operating
pressure of the pump They are installed at the pressure outlet of Function principle electric pressure switch
the pump and will switch off the pump if an overpressure occurs Operating temperature –25 to +85 °C, +13 to +185 °F
0–600 bar, 0–8 700 psi
Operating pressure
downstream in the system Input data measuring range 0–600 bar; 0–8 700 psi
overload pressure: 750 bar; 10 870 psi
burst pressure: 800 bar; 11 600 psi
Features and benefits Output data accuracy >=0,5% full scale
Analog output
signal 4–20 mA
Switching output type PNP transistor output
• Protects the system from damage
switching current max 0,5 A
caused by overpressure Supply voltage 18–36 V DC
1
Hydraulic connection G /4
• All parameters can be set by keypad Protection class IP 67
• Adjustable keypad lock Dimensions 94 × 34 × 49 mm; 3.7 × 1.34 × 1.93 in
Mounting position any
• Rugged construction, vibration and shock-proof
• Long-term stability
Order information
Applications Order number Designation
• Dual-line pumps
623-37567-1 Electric pressure switch with transducer kit for
• Steel mills 40 and 100 l, 10 and 26 gal, reservoir versions,
includes electronic pressure and digital display
• Cement plants
• Minerals and mining
NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
are available on SKF com/lubrication
67