Page 66 - Dual-line-automatic
P. 66
End - of - line pressure unit
EDW
Pressure sensors
Description
Technical data
EDW end-of-line pressure switches are key components in a
dual-line lubrication system Designed to monitor the system, Function principle electronic pressure switch with
these switches detect the pressure at the end of the respective Operating temperature 4-digit 7-segment LED display
–25 to +85 °C
main line and start the change-over procedure If the pressure at -13 to +185 °F
the end of the line is not reached within a specific period of time, Operating pressure 0–600 bar, 0–8 700 psi
1
Main line connection G /4 male
a fault signal will be generated at the electronic control unit Electrical connections 4 pin plug, M 12 × 1
Supply voltage 18–36 V DC
Dimensions 150 × 250 × 60 mm
Features and benefits 5.9 × 9.9 × 2.4 in
• Controls proper functioning of the pump and Protection class IP 67
change-over unit Mounting position any
• Monitors for leaks in the tube line system
• Available with limit switches or with
electronic pressure switches with LED display
Order information
• Proven, rigid design for tough conditions
Order number Designation
Applications 632-36501-1 EDW end-of-line pressure unit with limit switches
and pressure gauges
• Large dual-line systems
• Steel mills 632-36627-3 EDW end-of-line pressure unit with electronic
pressure switches with LED display
• Cement plants
• Minerals and mining
NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
are available on SKF com/lubrication
66