Page 64 - Single-line automatic lubrication systems
P. 64

Pump unit


        84944, 84961
     Pump units for grease






























        Description
                                                              Technical data
        Models 84944 and 84961 are pumping systems designed  to operate
        centralized lubrication systems that utilize single-line, parallel grease   Order number  84944
                                                                                  84961
        metering components. The pump is double acting, dispensing lubri-  Function principle  hydraulically operated,
        cant on both the up and down strokes. These units are designed for        double-acting piston pump
                                                              Outlets             1
        off-road equipment that utilizes 24 V DC power sources. These units
                                                              Metering quantity   180 cm  3 / stroke, 11 in  3 / stroke
        can be used in conjunction with:                      Lubricant           grease NLGI 0, 1, 2
        Models 244270 (not potted) or 249605 (potted) cycle timers;   Operating temperature  –40 to +57 °C; –40 to +135 °F
        Model 84944 hydraulically operated pump with 60 lb metal    Fluid inlet temperature  max. +99 °C; +210 °F
                                                                                  min. 20 bar, 300 psi
                                                              Hydraulic inlet pressure
        reservoir and vent valve (basic pump); and Model 84961 basic              max. 205 bar, 3 000 psi
        pump (similar to Model 84944 but without reservoir or vent valve).   Pressure ratio  16:1
                                                              Reservoir           27,0 kg; 60.0 lb
        These products include a pump and hydraulic control.   Material           steel, brass, copper, polyurethane, nitrile
                                                              Connection outlet   3 /4 NPTF (M)
                                                              Hydraulic inlet/outlet  1 /4 NPTF (M)
        Features and benefits                                 Flow rate           at 30 cycles/min: 3,8 l/min, 1.0 gal/min
                                                              Operating voltage   24 V DC
        •  Robust                                             Dimensions:
                                                              84944               381 × 495,3 × 889 mm
        •  Pump operates by an electrical signal                                  15 × 19.5 × 35 in
                                                              84961               76 × 177,8 × 866,8 mm
        •  Supplied with metal reservoir with removable cover                     3 × 7 × 34.125 in
          for easy filling                                    Mounting position   vertical
        •  Includes a hydraulic operated solenoid vent valve 24 V DC   Cycle timer
                                                              Voltage             24 V DC
        •  Includes a hydraulic pressure reduction valve rated    Cycle rate per min  min. 6, max. 60
          4 to 55 bar (60 to 800 psi) output
        •  Bulk filling method
        •  For use with metering devices of category  5, 6 and 7   NOTE
                                                                     Further technical information, technical drawings,
        Applications                                               accessories, spare parts or product function descriptions
                                                                   available on SKF.com/lubrication.
        •  Construction machinery
        •  Heavy machines
        •  Vehicles


                                                           64