Page 60 - Single-line automatic lubrication systems
P. 60

Pump unit


        82653/55, 83800/34
     Pump units for grease






























        Description
                                                              Technical data
        All models are air-operated, positive-displacement pumps
        delivering a maximum volume by means of a single stroke of the   Function principle  air operated piston pump (single-stroke)
                                                                                  1
                                                              Outlets
        pump. Solenoid air valves and adjustable, solid-state time controls   Metering quantity  22,9 to 35,2 cm  3 / stroke
        are integrated into the pump body. These pump units are designed to       1.4 to 2.15 in  3 / stroke
                                                              Lubricant           grease NLGI 0, 1, 2
        deliver grease to single-line metering devices and include a special
                                                              Operating temperature  –18 to +65 °C; 0 to +150 °F
        high-volume refill fitting. Translucent, acrylic reservoirs with spring-  Operating pressure  min. 82 bar, 1 200 psi
        loaded followers are available in several sizes. Pump uses air for for-   max. 240 bar, 3 500 psi
        ward and return stroke but dispenses lubricant  on forward stroke   Reservoir  2,0 kg; 4.5 lb
                                                                                  acrylic
                                                              Material
        only. Return stroke releases pressure on the lubricant line through   Connection outlet  1 /4 NPTF (F)
        included check/relief valve.                          Transmission ratio  31:1; 25:1
                                                              Air inlet           1 /4 NPTF (F)
                                                              Dimensions          470 × 146 × 533 mm
                                                                                  18.5 × 5.75 × 20.9 in
        Features and benefits                                 Mounting position   vertical
        •  Remote system components such as 4/2-way valves,    Timer (for 82655 and 83800 only)
          adjustments for air power, and monitoring of pump    On time            min. 10 sec
                                                                                  max. 1 minute, 24 sec
          and system are available separately on request      Cycle time          min. 20 sec
        •  High-volume refill fitting                                             max. 24 h
        •  For use with metering devices of category 5, 6 and 7   Operating voltage  120 V AC, 60 Hz; 110 V AC, 50 Hz
                                                              Operating temperature  –23 to +65 °C; –10 to +150 °F
        Applications

        •  Oil and gas industry
        •  Chain lubrication                                  Air consumption at 6,9 bar, 100 psi, is 0,004 M  3 /min, 0.15 ft  3 /min, per stroke


          Order information                                        NOTE
          Order number Ratio  Metering quantity  Designation         Further technical information, technical drawings,
                                                                   accessories, spare parts or product function descriptions
                           cm  3  / stroke in  3  / stroke         available on SKF.com/lubrication.

          82653      31:1  22,9     1.4    bare pump
          82655      31:1  22,9     1.4    pump with controls
          83800      25:1  35,2     2.15   pump with controls
          83834      25:1  35,2     2.15   bare pump


                                                           60