Page 161 - Single-line automatic lubrication systems
P. 161

Control unit


           EOT-1/2 664-34135-6, 664-34135-7




                                                                                                                      Control units

























           Description
                                                                Technical data
           EOT-1 / EOT-2 are time controllers for lubrication pumps in sin-
           gle-line or progressive lubrication systems. EOT-1 has a fixed run-  Function principle  control unit
           ning time of 4 seconds and flexible pause time adjustments and,   Supply voltage  12/24 V DC
                                                                 Max. current draw   ≤ 7 A
           therefore, is suitable for chain lubrication. EOT-2 features flexible   Protection class  IP 65 , SELV/PELV
           time settings. Both controllers are required if pumps without timers   Operating temperature  –25 to +70 °C; –13 to +158 °F
                                                                 Noise suppression   class A VDE 0875 T11
           are used in lubrication systems or there is no customer-related   Interference resistance  DIN EN 61000-6-1
           request for pumps with an integrated pump controller. It also is suit-  Transient emissions  DIN EN 61000-6-3
           able for retrofit installation. Simply set time using the red (running   Outputs  transistor/ no
           time) and a blue (pause time) switches and use the push-button to   EEPROM  non-dissipative storage of data
           activate an additional lubrication cycle for easy and safe pump   EOT 1
           operation.                                            Pause time          min. 5 sec, max. 75 min
                                                                 Running time        4 sec, unvaried
                                                                 EOT 2
           Features and benefits                                 Pause time          min. 4 min, max. 15 h
                                                                 Running time        min. 8 sec, max. 30 min
           •  Time controller for installation in driver's cabin
           •  Suitable for retrofit                              Factory setting
           •  Simple handling of time setting and function control  EOT 1            15 sec
                                                                 Pause time
                                                                 Running time        4 sec
           Applications                                          EOT 2               6 min
                                                                 Pause time
           •  Agriculture                                        Running time        4 sec
           •  Chain lubrication systems                          Dimensions          122 × 118 × 56 mm
                                                                                     4.8 × 4.6 × 2.2 in
                                                                 Mounting position   any



            Order information                                        NOTE
                                                                       Further technical information, technical drawings,
            Order number  Designation
                                                                     accessories, spare parts or product function descriptions
                                                                     available on SKF.com/lubrication:
            664-34135-6   EOT 1 controller for SKF Lincoln EOP pumps
                                                                     951-181-005 EN
            664-34135-7   EOT 2 controller for one pump unit (not EOP)
                                                                     3D
                                                                     skf-lubrication partcommunity com/3d-cad-models


                                                            161