Page 157 - Single-line automatic lubrication systems
P. 157

Control unit


           ST-102




                                                                                                                      Control units

























           Description
                                                                Technical data
           The ST-102 controller is designed for the control and monitoring
           of single-line, dual-line and progressive lubrication systems in    Order number  11500610
           vehicles with a 12 or 24 V DC power supply. It is a one-channel
                                                                 Function principle  control and monitoring device
           lubrication control centre for systems with pneumatic or electrical   Operating temperature  -30 to +80 °C; -22 to +176 °F
           pumps. The ST-102 is suitable for environments with temperatures   Power supply  12 and 24 V DC; (10,5  to 32 V DC)
                                                                 Pump output control  max. 5 A
           ranging from -30 to +80 °C (-22 to +176 °F) and features an IP 30   Protection class  IP 30
           protection class. All lubrication configurations can be set in the field   Self-setting fuse  4 A on pcb
           by the user.                                          Time, cycle settings:
                                                                   Max. pressurization time  1 to 20 min
                                                                   Interval time     5, 10…120 min
           Features and benefits                                   Pressurization time  1,2,3…10 min
                                                                 Interface           1-button user interface, 3 LED’s
           •  Available for 12 or 24V DC                         Input               4 digital
                                                                 Output              4 digital
           •  Suitable for operational environments              Standard            CE
             with extreme temperatures                           Dimensions          26 × 60 × 160 mm
                                                                                     1.02 × 2.36 × 6.3 in
           •  One-button user interface                          Mounting position   vertical
           •  Power failure memory


           Applications
           •  Service vehicles
           •  Construction machinery
           •  Agriculture machinery


                                                                     NOTE
                                                                       Further technical information, technical drawings,
                                                                     accessories, spare parts or product function descriptions
                                                                     available on SKF.com/lubrication:
                                                                     6408 EN