Page 105 - Single-line automatic lubrication systems
P. 105

Metering device

                                                                                                                      Metering devices for oil
           350



                                     3 5           –                 –                           –
            Identification code



            Product series
            Number of metering points (2, 3, 5)




            Design and metering quantity                              Fittings for main line connection
                                                                                               Main line
            Design code  0      8       1        7                    Designation              [mm]      Code
            Lubricant    Oil    Oil     Fluid grease Fluid grease                              6         B
                                                                      Straight adapter
            ∅ Outlet [mm]  4    4       4        4                    DIN 3862 with flat washer  1)  8   C
                                                                                               10        D
            Metering nipple  Brass  Brass  Brass (n.p.) Brass (n.p.)  Banjo fitting DIN 3862   6         E
                                                                      with flat washer, lockable  1) 2)  8  F
            Elastomer    NBR    FKM (FPM) NBR    FKM (FPM)
                                                                      Screw plug with flat washer  –     H
            Connection outlet VS  00 VS  00  VS  00  VS  00
                                                                                               6         M
                                                                      Straight adapter         8         N
                 0,05 cm  3  3  3  3  3  –  –    –   –                with EO-2 functional nut  10       P
                 0,10 cm  3  4  4  4 5  4  4  4 5  4  4 5             Straight adapter         12        R
                         5
                 0,20 cm  3
                                        5
                                                 5
                             5
                                    5
                                                                                                         S
                                                                                               6
              Metering    quantity code  0,30 cm  3  – 6  – 6  – 6  – 6  6  6 – 7  6  6  with SKF Quick Connector  8 6 8  T
                                                     -
                                                 –
                                        –
                 0,40 cm  3
                                                                      Banjo fitting with
                                                                                                         W
                                    7
                             7
                                7
                                                     –
                                                 –
                                        –
                 0,60 cm  3
                         7
                                                                                                         X
                                                                      SKF Quick Connectors
                                            V
                                        V
                                                 V
                                                     V
                 closed*
                                    V
                             V
                                V
                         V
                                                                      Without fitting (M12x1 thread)  –  Z
                                                                     1)   Solderless pipe connection according to DIN 3862 (operating pressure max. 45 bar)
              V = Metering quatity of 0,20 cm  3 , closed            2)   Banjo bolt only inserted in delivery condition, not tightened
           Accessory
           Exchangeable metering nipples
            Order numbers for metering nipples for oil (replaceable)
            Outlet ∅    Material   Metering   Metering quantity
                        elastomer  nipple
                                           0,05 cm  3    0,10 cm  3     0,20 cm  3     0,40 cm  3     0,60 cm  3
            mm    in                       0.003 in  3   0.006 in  3  0.012 in  3   0.024 in  3   0.036 in  3
            4     0.16  NBR      00        352-005-K     352-010-K    352-020-K     352-040-K     352-060-K
            4     0.16  NBR      VS        352-005-VS    352-010-VS   352-020-VS    352-040-VS    352-060-VS
            4     0.16  FKM (FPM)  00      352-005-K-S8  352-010-K-S8  352-020-K-S8  352-040-K-S8  352-060-K-S8
            4     0.16  FKM (FPM)  VS      352-005-S8-VS  352-010-S8-VS  352-020-S8-VS  352-040-S8-VS  352-060-S8-VS
            Order numbers for metering nipples for fluid grease (replaceable)
            Outlet ∅    Material   Metering   Metering quantity
                        elastomer  nipple
                                           0,10 cm  3       0,20 cm  3       0,30 cm  3       0,60 cm  3
            mm    in                       0.006 in  3      0.012 in  3      0.018 in  3      0.036 in  3
            4     0.16  NBR      00        995-993-610      995-993-620      995-993-630      995-993-660
            4     0.16  NBR      VS        995-993-610-VS   995-993-620-VS   995-993-630-VS   –
            4     0.16  FKM (FPM)  00      352-010-K-S82    352-020-K-S82    352-030-K-S82    –
            4     0.16  FKM (FPM)  VS      352-010-S82-VS   352-020-S82-VS   352-030-S82-VS   –
                                                            105