Page 238 - Y-bearing-units
P. 238

Y-bearing take-up units

        Designs                                                           Fig. 1

        Y-bearing take-up units consist of a cast  housing
        and an insert bearing († fig. 1). These units
        are typically mounted in take-up frames and
        connected by an adjustment screw. A grease fitting
        is provided in the housing for relubrication.
        Standard Y-bearing take-up units can be located
        on the shaft via the inner ring  of the insert
        bearing with either:

        •  grub (set) screws
        •  an eccentric locking collar
        The Y-bearing is sealed with either:

        •  the standard integral seal
        •  the standard integral seal and an additional
          flinger                                                         Fig. 2

        For additional information about Y-bearings,
        refer to the section Y-bearings, starting on
        page 79.

        Data – general
                                                                    H 1
        Dimensions
        The boundary dimensions of SKF Y-bearing
        take-up housings in the:
        •  TU series are in accordance with
          ISO 3228:1993                                     A 1
        •  TUJ series are in accordance with
          JIS B 1559-1995

        Tolerances
        The tolerances († fig. 2), which are in accordance
        with ISO 3228:1993, are:
        •  ± 0,25 mm for the distance between the
          guide surfaces H 1
        •  within the tolerance range H13 for the width
          of the guide surfaces A 1
        Information about the tolerances of the inner
        ring bore diameter can be found in the section
        Y-bearings on page 89.





        236