Page 31 - Multi-line-automatic
P. 31

Overview of multi-line grease pumps


                                                                                                                      Pump units for grease


            Hydraulically operated pump units

            Product   Lubricant    Outlets  Reservoir  6)    Metering quantity per outlet  Operating pressure    Page
                      grease                                                         max
                      NLGI

                      0 1 2 3               kg        lb     cm 3 /min  in 3 /min    bar   psi

            PFHM-ATEX • • • –      1 – 6    6         12     0,80-5,00  0.048-0.305  250   3 625          32


            Mechanically operated pump units

            Product   Lubricant    Outlets  Reservoir  6)      Metering quantity per outlet    Operating pressure  ATEX  3)  Page
                   grease                                                          max
                   NLGI
                   0 1 2 3             kg        lb            cm 3 /min  in 3 /min  bar  psi


            RA 20 / 45 • • • –  1 – 12  2 – 5    4.4 – 10      0,07–6,00  0.004–0.366  60  870     •  4)   34
            P 205  • • • –    1 – 5    4 – 30    8.8 –  66     0,08–4,20  0.005–0.256  350  5 075  •  5)   36
            FF     • • • •    1 – 12   4 – 10    8.8 – 22      0,04–6,90  0.002–0.421  350  5 075  •  4)   38
            P 215  2)  • • • –   1 – 15  4 – 100  8.8 – 220    0,55–3,15  0.033–0.192  350  5 075  •  5)   42
            FB     • • • •    1 – 24   6 – 30    13 –  66      0,04–7,70  0.002–0.469  350  5 075  •  4)   44

            P 230  • • • –    1 – 30   30 – 100  66 –  220     0,55–3,15  0.033–0.192  350  5 075  •       48





            Electrically operated pump units  1)
            Product   Lubricant    Outlets  Reservoir  6)      Metering quantity per outlet    Operating pressure  ATEX  3)  Page
                    grease                                                         max
                    NLGI
                    0 1 2 3           kg        lb             cm 3 /min  in 3 /min  bar  psi

            RA 20 / 45 • • • –  1 – 12  2 – 5   4.4 – 10       0,07–6,00  0.004–0.366  60  870     •  4)  34
            P 205   • • • –   1 – 5   4 – 30    8.8 –  66      0,08–4,20  0.005–0.256  350  5 075  •  5)  36
            FF      • • • •   1 – 12  4 – 10    8.8 – 22       0,04–6,00  0.002–0.366  350  5 075  •  4)  38
            P 212  2)  • • • –  1 – 12  30      66             2,50–25,0  0.152–1.525  350  5 075  •      40

            P 215  2)  • • • –  1 – 15  4 – 100  8.8 – 220     0,55–3,15  0.033–0.192  350  5 075  •  5)  42
            FB      • • • •   1 – 24  6 – 30    13 – 66        0,04–7,70  0.002–0.469  350  5 075  •  4)   44
            FB-XL   • • • •   1 – 16  30        66             0,04–35,0  0.002–2.135  350  5 075  •  4)   44
            P 230   • • • –   1 – 30  30 – 100  66 – 220       0,55–3,15  0.033–0.192  350  5 075  •      48


           1)    all data based on 50 Hz operation for connection with a frequency of 60 Hz, the speed and volumetric flow are increased by 20%
           2)   NLGI 3 on request
           3)   on request
           4)   for gas: II 2G c IIC T4 Gb; for dust: II 2D c IIIC T 125°C Db
           5)   for gas: II 2G c IIC T4 Gb; for dust: II 2D c IIIC T 120°C Db
           6)    valid for ρ=1 kg/dm 3
                                                             31
   26   27   28   29   30   31   32   33   34   35   36