Page 23 - Multi-line-automatic
P. 23

Pump unit


           PC

                                                                                                                      Pump units for oil

            Identification code                PC                           A    1        C



            Product series
            Size
              2 = 2 modules, max  8 outlets  5 = 5 modules, max  20 outlets
              3 = 3 modules, max  12 outlets  6 = 6 modules, max  24 outlets
              4 = 4 modules, max  16 outlets  7 = 7 modules, max  28 outlets
            Mounting plate position
              B = top (floor)
              R = rear (rear wall)
            Drive type
              1M = worm drive with electric motor
              1Y = worm drive with hydraulic motor
            Pump location and front label design
              VM = front side mounted, multi level, 1 upper level, 1 lower level, 2 upper level
              VS = front side mounted, single level, 1, 2, 3, 4     x
              HM = rear side mounted, multi level, ×     4 upper level, 4 lower level, 3 upper level

              HS = rear side mounted, single level, ×     4, 3, 2, 1

            Gear reduction
              14 = 14,5:1 for drive type 1M  51 = 51:1 for drive type 1M
              19 = 19:1 for drive type 1M  62 = 62:1 for drive type 1M
              29 = 29:1 for drive type 1M  05 = 4,83:1 for drive type 1Y
              38 = 38:1 for drive type 1M  07 = 7,25:1 for drive type 1Y
            Drive position
             A = motor at left
            Pump element
             1 = piston ∅ 10 mm

            Outlets
             01 = 1 outlet;        28 = 28 outlets
            Outlet connection for tube ∅ OD
             C = 10 mm
            Design key
              A0001 = basic version, electric motor with GL approval, NAMUR sensor incl  terminal box, colour Munsel 7,5 BG7/2
              A0002 = basic version, with tachometer
              A0003 = basic version, sensor type NPN instead of NAMUR
              A4002 = basic version, sensor type NPN instead of NAMUR, without terminal box
              A4003 = basic version, sensor type NPN instead of NAMUR, without terminal box, with revolution sensor
              A4004 = basic version, including oil troy and mounting bracket
              A4005 = same as A0003, with revolution sensor
            Motor code
              AS07 = 3-phase standard motor 255/460 V 60 Hz, n = 1 740 min -1 , IP 55F
              HM00 = hydraulic motor Danfoss OMR100


            PC accessories

            Order number     Description
            24-0404-2493     gasket set with seals
            24-1557-3560     spare pumping element
            24-1751-2760     filter assembly, 100 mµ
            24-0651-3519     filter element only