Page 38 - Single-line automatic lubrication systems
P. 38

Pump unit


        KFB-M
     Pump units for oil





























        Description
                                                              Technical data
        Used with SKF MonoFlex single-line systems, the KFB series gear
        pump units supply fluid grease NLGI 000 and 00 and include a pres-  Function principle  electrically operated gear pump
                                                              Outlets
                                                                                      1
        sure-relief valve and a pressure-limiting valve. The pumps are   Metering quantity  1)  50 cm  3 / min, 3.05 in  3 / min
        designed for supply voltages of 24 V DC and are controlled either by   Lubricant  fluid grease of NLGI grade 000 or 00
                                                              Operating temperature   0 to +60 °C; +32 to +140 °F
        an integrated electronic control unit or externally, via the machine
                                                              Operating pressure      max. 38 bar, 550 psi
        control system. Depending on the design, the gear pump units are   Reservoir  KFB1-M: 1,4 l, 0.37 gal
        filled via a filler socket or attached filler coupling.                       KFB(S)1-M(-W): 1 l, 0.26 gal
                                                              Material (reservoir)    translucent plastic
                                                              Connection outlet       ∅ 8 × 1,25 (max. 16 m, 52.5 ft)
                                                              Dimensions:
        Features and benefits                                 KFB1-M, KFB1-M-W, KFBS1-M,   216 × 150 × 235 mm
                                                              KFBS1-M-W               8.5 × 5.9 × 9.3 in
        •  Compact pump unit
                                                              KFB1-M-W-S1             216 × 150 × 270 mm
        •  Integrated pressure-relief valve and pressure-regulating valve             8.5 × 5.9 × 10.6 in
        •  Visual or optional electrical fill-level monitoring  Mounting position     vertical
        •  Optional integrated control                        DC motor
                                                              Voltage                 24 V DC  2)
                                                              Current                 1,7 A
                                                              Rated output            41 W
        Applications                                          Protection class        IP 65
        •  Automation                                         Fill-level switch (KFB1-M-W) (change-over contact)
                                                              Switching voltage       24 V DC  2)
        •  Automotive                                         Switching current (resistive load)  3) ≤0.5 A
        •  Machine tools                                      Switching capacity (resistive load)  3) ≤12 W
                                                              Control unit IG502-2-I (KFBS1)
                                                              Interval, adjustable    0.1 ... 99.9 h
                                                              Pump run time, adjustable  0.1 ... 99.9 min
              NOTE                                            Max. pump run time      2.4 min
                                                              Elapsed-hours counter   0 ... 99999.9 h
                Further technical information, technical drawings,
                                                              Fault-hours counter     0 ... 99999.9 h
              accessories, spare parts or product function descriptions   Additional input power for
              available on SKF.com/lubrication:               units with control unit
              1-1206-EN; 951-170-009                          (without output load)   4 W
              3D                                              1)   At back pressure of 10 bar and a temperature of +25 °C; +77 °F
                                                              2)   Safety measures to be applied for correct operation:
              skf-lubrication partcommunity com/3d-cad-models   Protective extra-low voltage (PELV), standards: EN 60204-1/IEC 60204-1;
                                                                HD 60364-4-41/DIN EN 0100-410/IEC 60364-4-41
                                                              3)   When switching inductive loads, take appropriate measures to protect contacts.