Page 129 - Single-line automatic lubrication systems
P. 129
Overview of grease metering devices
Metering devices for grease Metering devices for grease
Single-line metering devices
Product Cate- Lubricant Metering quantity Operating pressure Relief pressure Adjustable Function type Page
gory 1) grease max. max. metering
NLGI quantity
0 1 2 cm 3 /stroke in 3 /stroke bar psi bar psi
SL-33 2) 5 • • – 0,016–0,05 0.0009–0.0030 83-240 1 200-3 500 14 200 • prelubrication 130
B-doser 2) 5 • • – 0,02–0,50 0.0012–0.0305 max. 150 max. 2 180 15 3) 218 3) • prelubrication 132
LG-doser 2) 5 • • – 0,02–0,50 0.0012–0.0305 max. 150 max. 2 180 10 3) 145 3) • prelubrication 134
SL-32 HV 2) 6 • • • 0,016–0,13 0.0009–0.0079 83–240 1 200–3 500 28 400 • prelubrication 136
SL-1 2) 6 • • • 0,13–1,31 0.0079–0.0799 127–240 1 850–3 500 41 600 • prelubrication 137
QSL 2) 7 • • • 0,05–0,40 0.0030–0.0244 140–300 2 030–4 350 60 870 • prelubrication 138
VR 2) 7 • • • 0,10–1,30 0.0061–0.0793 100–315 1 450–4 570 30 3) 435 3) • prelubrication 140
70 3) 1 000 3) • prelubrication
SLC 7 • • • 0,10–1,40 0.0061–0.0840 150–315 2 175–4 570 68 990 • prelubrication 142
SL-11 7 • • • 0,82–8,20 0.0500–0.5002 70–240 1 000–3 500 55 800 • prelubrication 144
SL-V 7 • • • 0,25–1,31 0.0152–0.0799 128–413 1 850–6 000 70 1 000 • prelubrication 145
SL-V XL 7 • • • 0,25–5,00 0.0152–0.3050 128–413 1 850–6 000 70 1 000 • prelubrication 146
1) The category allows a simple assignment of the metering device to a pump of the same category. The category results from the relief pressure,
the operating principle and the lubricant suitable for the metering device.
2) Stainless steel or C5M available
3) Depending on design
129