Page 8 - Multi-line-automatic
P. 8

Multi-line lubrication systems for grease









     Introduction




































        System description

        SKF multi-line lubrication systems consist of the following   SKF multi-line grease pumps are designed for demanding
        components: a pump unit, control and monitoring devices,   applications in nearly all industries  Most pump versions are
        tubing and fittings  Multi-line pump units supply lubricant to   available with special reservoirs for oil  The P 215 and P 230
        lubrication points without extra metering dividers  Thus, each   pump series enable the use of plasticizer oil for the
        lubrication point has its own pumping element  The system   rubber industry
        design is simple, accurate and most reliable
        Multi-line pumps can be actuated mechanically,  electrically or   Advantages:
        hydraulically  The easily exchangeable pumping elements are   •  Sturdy; durable pump series designed
        usually operated by eccentric cam  Depending on the drive   for 24/7 operation
        speed, gearbox ratio and selected pump element size, a deliv-
                                   3
                                                  3
        ery range from almost 0 to 35 cm /min (0 to 2 13 in /min) can   •  Simple; continuous lubrication without
        be covered  The built-in stirrer mixes the grease (grease sof-  electrical cycle timers, in most cases
        tening process), is synchronized with the pump element suc-  •  Versatile; select individual pump element
        tion stroke, and assists the heavy lubricant to flow into the   characteristics and reservoir size
        suction chamber  This unique concept supplies heavy lubri-  •  Precise; set the required stroke volume
        cants usually up to NLGI 3
                                                               at the pumping element
        An individual lubrication volume setting per pump outlet is   •  Due to the use of a built-in stirrer and
        possible by selecting pumping elements with different piston    broad viscosity range, heaters are not required
        diameters and/or stroke settings  The potential numbers of
        outlets range from 1 to 30                           •  ATEX explosion-proof versions available
                                                             •  Extra, downstream-located flow control valves
                                                               or progressive metering devices possible



                                                           8