Control unit
EOT - 2
Control units
Product description
Technical data
The EOT-2 controller is designed to control lubrication
pumps during interval operation in multi-line systems Function principle control and monitoring device
Rotary switches on the printed circuit board may be used to Operating temperature –25 to +70 °C, –13 to +158 °F
Supply voltage
12 or 24 V DC
adjust lubrication time in seconds or minutes and pause time Current draw max ≤ 7 A
in minutes or hours The EOT-2 is suitable for retrofit installa- Outputs transistor / N O
min 4 min
Pause time
tion and often is used when a lubrication pump has no inte- max 15 h
grated control unit Additional lubrication cycles can be Running time min 8 sec
triggered via a pushbutton max 30 min
Standard CE
Protection class IP 65
Features and benefits Dimensions 122 × 118 × 56 mm,
4.80 × 4.65 × 2.00 in
• Easy-to-use controller for installation, indoor and outdoor Mounting position any
• Suitable for retrofit , easy time setting and function control
Order information
Applications
Order number Description
• Lubrication pumps without integrated controller
• Agricultural machinery, chain lubrication systems 236-10850-7 EOT-2 controller with motor starter 0,4–0,6 A
236-10850-8 EOT-2 controller with motor starter 0,6–1,0 A
• Simple lubrication systems in machines 236-10850-9 EOT-2 controller with motor starter 1,0–1,6 A
236-10980-6 EOT-2 controller with motor starter 2,4–4,0 A
• In connection with motor relay assembly;
also preferred for three-phase, multi-line pump units 664-34135-7 EOT-2 controller, for one pump only