Change-over valve
MP 2
Valves
Description
Technical data
Designed for use in dual-line systems, the pneumatically operated
MP 2 change-over valve works like a 4/2-way valve It alternately Function principle change-over valve, hydraulic,
discharges the lubricant fed by the pump into one of the main lines Operating temperature pressure operated 4/2 way valves
–20 to +70 °C
while the other main line is connected to the pump’s return line –4 to +158 °F
connection Lubricant grease up to NLGI 3,
oil with a viscosity of min 20 mm 2 /s
Flow rate 65 dm 3 /h, 17 gal/h
Features and benefits Operating pressure max 400 bar, 5 800 psi
Compressed air pressure max 10 bar, max. 145 psi
• Available in four voltages – Operating hydraulic pressure max 69 bar, max. 870 psi
3
G /4 female BSPP
Main line connection
24 and 110 V DC, 110 and 220 V AC Voltage 24 or 110 V DC, 110 or 220 V AC
Protection class IP 65
• Can be used as a 3/2-way valve for grease systems Dimensions 135 × 400 × 180 mm
• Maximum operating pressure of 400 bar (5 800 psi) 5.4 × 16 × 7.2 in
Mounting position any
• Works effectively in temperatures ranging
from –20 to +70 °C (–4 °F to +158 °F)
Applications
• Particularly suitable in connection with pneumatically
operated pumps like PowerMaster or Lubrigun
• Bottle filling machines in food and beverage plants
• For small, medium and large dual-line systems
MP 2 Change-over valves NOTE
Further technical information, technical drawings,
Order number Designation Voltage
accessories, spare parts or product function descriptions
618-28965-2 MP 2-24 V DC 24 V DC are available on SKF com/lubrication
618-28963-1 MP 2-110 V DC 110 V DC
618-28964-2 MP 2-110 V AC 110 V AC
618-28966-2 MP 2-220 V AC 220 V AC