Page 19 - Dual-line-automatic
P. 19

Pump unit


           ZPU 08 / 14 / 24




            Identification code                            ZPU            –                 –
                                                                                                                      Pump units


            Product series
            Metering quantity
             08 = 8 000 cm 3 /h, 488 in 3 /h
             14 = 14 000 cm 3 /h, 855 in 3 /h
             24 = 24 000 cm 3 /h, 1 465 in 3 /h
            Drive assemblies
             F   = with free shaft end
             G   = with flanged gear motor construction IMB5
             S   = with worm gear and 3-phase motor construction IMV1
             SF   = with worm gear and shaft end, suitable for 3-phase motor construction
             S /SF is only available for model  ZPU 08
            Reservoir capacity
             040 = 40 l, 10 gal
             100 = 100 l, 26 gal
            Reservoir design
             XN   = grease reservoir, standard design
             XL    = grease reservoir with low-level control
             XB   = grease reservoir with high- and low-level control
             XYBU  = reservoir with low- and high-level control via ultrasonic sensor
            Extension for motor designation
             380-415/440-480 = standard multi-range motor for 380-415 V AC/50 Hz, and 420-480 V AC/60 Hz
             500              = 500 V AC/50 Hz











































                                                             19