Page 6 - Progressive_automatic_lubrication_systems
P. 6

Progressive lubrication systems




                                                                                                     System video



     Introduction




































        System description

        SKF progressive systems, SKF ProFlex and Lincoln Quicklub, can be   Oil Circulation Systems  SKF progressive systems provide continuous
        used on small- to medium sized machines with dispersed lubrication   lubrication as long as the pump is in operation  Once the pump stops,
        points that require varying lubrication quantities   the pistons of the progressive metering device will stop in their cur-
                                                             rent positions  When the pump starts supplying lubricant again, the
        Progressive systems consist of a pump connected to at least one
                                                             pistons will carry on where they left  Therefore, the progressive
        primary metering device  If needed, second level metering devices
                                                             circuit of one outlet of the pump will stop when only one lubrication
        can be connected to the outlets of the primary metering device to
                                                             point is blocked  The blockage serves as a means of control and
        increase the number of lubricated points, depending on operating
        pressure of the pump  The outlets of the primary and second level   forces personnel to service the system  Only one outlet of a primary
        metering devices are connected via branch lines to the lubrication   or a secondary metering device of one pump outlet can be monitored
        points of the machine  A third level of metering devices is not recom-  visually or electrically, depending on the chosen metering device
        mended  The pump supplies lubricant to the metering devices with   For planning a lubrication system, conditions the system will be used
        pressure up to 550 bar (8 000 psi), depending on the pump model   in need to be determined first  The number of lube points, back pres-
                                                             sures at the lube points, operating temperature range, lubricant, the
        The metering devices split the lubricant into even or predefined
                                                             feed pump’s drive energy, control and monitoring etc  need to be
        amounts of lubricant, depending on metering device, that are posi-
        tively displaced to the lubrication points or to the inlet of a connected   defined correctly  Attention to information on bearing or lube point
        secondary metering device  The lubricant amount provided by each   information need to be paid too  The sum of all the quantities
        outlet of the metering device depends on the type of metering device   metered out by the system’s metering devices needs to be completed
                                                             by safety margin and expansion and compressibility loss  SKF appli-
        being used  SKF offers progressive systems that can dispense a
                                                             cation engineers as well as SKF sales partners and distributors are
        precise, metered amount of lubricant to up to 150 lubrication points
                                                             experts in systems laying out lubrication according to all these speci-
        over distances of approximately 15 m (16 yd), depending on case
        values  For oil applications, even in connection with flow limiters    fications  A lubrication system layed out by SKF and partners ensures
        we can cover distances oveR 100 m (110 yd), see also SKF Lincoln   the supply of the correct amount of lubricant at the best time to
        lubrication solutions portfolio brochure             lubricate  This reduces wear and it avoids pollution caused by
                                                             over-lubrication

                                                            6